引用本文:   黄煜宇, 肖坤, 裴兴丽, 韩玉良, 龚灿, 许旭. 使用尖玻片、毛细管和尖滴管三种玻璃尖端电喷雾离子化质谱分析方法. 分析化学, 2018, 46(4): 578-585. doi:  10.11895/j.issn.0253-3820.171305 [复制]

Citation:   HUANG Yu-Yu, XIAO Kun, PEI Xing-Li, HAN Yu-Liang, GONG Can, XU Xu. Three Glass Electrospray Ionization Devices for Direct Mass Spectrometry Analysis Using Sharp Slide, Slender Capillary and Sharp Dropper. Chinese Journal of Analytical Chemistry, 2018, 46(4): 578-585. doi: 10.11895/j.issn.0253-3820.171305 [复制]

使用尖玻片、毛细管和尖滴管三种玻璃尖端电喷雾离子化质谱分析方法

通讯作者:  许旭, xuxu3426@sina.com; xuxu@sit.edu.cn

收稿日期: 2017-10-09

接受日期: 2018-01-10

出版日期: 2018-04-01

基金项目: 本文系国家自然科学基金项目(No.31671928)和上海市自然科学基金项目(No.15ZR1440800)资助

Three Glass Electrospray Ionization Devices for Direct Mass Spectrometry Analysis Using Sharp Slide, Slender Capillary and Sharp Dropper

Corresponding author:  XU Xu, xuxu3426@sina.com; xuxu@sit.edu.cn

Received Date:  2017-10-09

Accepted Date:  2018-01-10

Published Date:  2018-04-01

Fund Project:  This work was supported by the National Natural Science Foundation of China (No.31671928) and Natural Science Foundation of Shanghai, China (No.15ZR1440800)

建立了用于质谱分析的尖玻片、毛细管、尖滴管3种基于玻璃尖端电喷雾的离子化新方法。通过模拟实验与实际质谱实验,考察了各种实验条件的影响。在喷雾尖端直径小于0.24 mm时,选择喷雾尖端针与反相电极距离10 mm,喷雾电压4.5 kV,喷雾尖端角度为后部偏上5.0°(尖玻片)~7.5°(细毛细管或尖滴管)、左右角度为0°(均对准中间)。选择奎宁、扁桃酸、安息香、苯丙氨酸等不同类型样品的溶液(正离子检测含1%甲酸,负离子检测含1%氨水)置于玻片上或者毛细管与尖滴管后部容器中,进行尖端喷雾直接分析。样品在正离子与负离子模式下分别得到了相应的质谱信号。尖玻片喷雾适合比较稳定、对空气不敏感的样品;毛细管喷雾和尖滴管喷雾则适合分析粘度较低,甚至不稳定的样品溶液。使用本方法实际分析了盐酸普萘洛尔和盐酸小檗碱片剂的提取溶液。3种玻璃尖端电喷雾方法均不需要载气,结构简单、易于构建、操作方便快速,可方便地用于样品溶液的质谱分析。

关键词:   质谱离子化, 质谱进样, 尖端喷雾, 玻璃喷雾
Key words:   Mass spectrometry ionization, Mass spectrometry injection, Sharp electrospray, Glass electrospray
[1]

Wang H, Liu J J, Cooks R G, Ouyang Z. Angew. Chem. Int. Edit., 2010, 49(5): 877-880. doi: 10.1002/anie.200906314

[2]

Liu J J, Wang H, Manicke N E, Lin J M, Cooks R G, Ouyang Z. Anal. Chem., 2010, 82(6): 2463-2471. doi: 10.1021/ac902854g

[3]

LIU Jing-Jing, HE Xiao-Wei, HE Yan, YU Mu-Qian, JIANG Le, CHEN Bo. Prog. Chem., 2017, 29(6): 659-666. doi: 10.7536/PC170352

刘婧靖, 何晓伟, 何燕, 喻目千, 蒋乐, 陈波. 化学进展, 2017, 29(6): 659-666. doi: 10.7536/PC170352

[4]

Teodoro J A R, Pereira H V, Sena M M, Piccin E, Zacca J J, Augusti R. Food Chem., 2017, 237: 1058-1064. doi: 10.1016/j.foodchem.2017.06.062

[5]

Liu J J, Deng W J, Yu M Q, Wen R Z, Yao S Z, Chen B. J. Pharmaceut. Biomed. Anal., 2017, 145: 151-157. doi: 10.1016/j.jpba.2017.06.030

[6]

Huang H, Wu Q C, Zeng L, Wan L, Lai S Q, Yin X J, Huang J F, Yang B C, Liu J C. Anal. Methods, 2017, 9(29): 4282-4287. doi: 10.1039/C7AY01169E

[7]

Wang T, Zheng Y J, Wang X T, Austin D E, Zhang Z P. Anal. Chem., 2017, 89(15): 7988-7995. doi: 10.1021/acs.analchem.7b01296

[8]

Meher A K, Chen Y C. RSC Adv., 2015, 5(114): 94315-94320. doi: 10.1039/C5RA17878A

[9]

Yang Q, Wang H, Maas J D, Chappell W J, Manicke N E, Cooks R G, Ouyang Z. Int. J. Mass Spectrom., 2012, 312(2): 201-207

[10]

Falcone C E, Cooks R G. Rapid Commun. Mass Spectrom., 2016, 30(11): 1304-1312. doi: 10.1002/rcm.7561

[11]

Pereira I, Rodrigues S R M, de Carvalho T C, Carvalho V V, Lobón G S, Bassane J F P, Domingos E, Romão W, Augusti R, Vaz B G. Anal. Methods., 2016, 8(31): 6023-6029. doi: 10.1039/C6AY01154C

[12]

Liu J J, Wang H, Cooks R G, Ouyang Z. Anal. Chem., 2011, 83(20): 7608-7613. doi: 10.1021/ac2020273

[13]

Müller T, Cooks R G. Bull. Korean Chem. Soc., 2014, 35(35): 919-924

[14]

Hu B, Huang Y Y, Yin G, Zhang G F, Zhang L Y, Wang T J, Yao Z P. Anal. Methods, 2016, 8(38): 6840-6846. doi: 10.1039/C6AY01735E

[15]

Hu B, So P K, Chen H W, Yao Z P. Anal Chem., 2011, 83(21): 8201-8207. doi: 10.1021/ac2017713

[16]

Yang Y Y, Deng J W, Yao Z P. J. Am. Soc. Mass Spectrom., 2014, 25(1): 37-47. doi: 10.1007/s13361-013-0748-0

[17]

Bedair M F, Oleschuk R D. Anal. Chem., 2006, 78(4): 1130-1138. doi: 10.1021/ac0514570

[18]

Wong M Y M, Tang H W, Man S H, Lam C W, Che C M, Ng K M. Rapid Commun. Mass Spectrom., 2013, 27(6): 713-721. doi: 10.1002/rcm.v27.6

[19]

Gibson G T T, Wright R D, Oleschuk R D. J. Mass Spectrom., 2012, 47(3): 271-276. doi: 10.1002/jms.2039

[20]

Jiang J, Zhang H, Li M, Dulay M T, Ingram A J, Li N, You H, Zare R N. Anal. Chem., 2015, 87(16): 8057-8062. doi: 10.1021/acs.analchem.5b02390

[21]

Tascon M, Goómez-Ríos G A, Reyes-Garceés N, Poole J, Boyacı E, Pawliszyn J. Anal. Chem., 2017, 89(16): 8421-8428. doi: 10.1021/acs.analchem.7b01877

[22]

Smith D P H. IEEE Trans. Ind. Appl., 1986, IA-22(3): 527-535. doi: 10.1109/TIA.1986.4504754

[23]

Pramanik B N, Ganguly A K, Gross M L. Applied Electrospray Mass Spectrometry, 1st. New York, 2002

[24]

Ren Y, Wang H, Liu J J, Zhang Z P, Mcluckey M N, Ouyang Z. Chromatographia, 2013, 76(19-20): 1339-1346. doi: 10.1021/ac00015a030

[25]

Chowdhury S K, Chait B T. Anal. Chem., 1991, 63(15): 1660-1664. doi: 10.1021/ac00015a030

[26]

赵海燕, 龚灿, 许旭. 分析化学, 2017, 45(9): 1323-1329

计量
  • PDF下载量(18)
  • 文章访问量(317)
  • HTML全文浏览量(3)

目录

使用尖玻片、毛细管和尖滴管三种玻璃尖端电喷雾离子化质谱分析方法

黄煜宇, 肖坤, 裴兴丽, 韩玉良, 龚灿, 许旭

Figures and Tables