会员登陆: 用户名:  密码: 验证码:
首页 杂志概况 投稿须知 在线投稿 在线阅读 征订启事 广告服务 行业资讯 企业动态 资料中心  专访报道 会展信息 ENGLISH

引用本文:   喻佳俊, 刘平, 曾真, 陈颖, 高伟, 李梅, 王晨光, 黄正旭, 周振, 李磊. 直线式基质辅助激光解吸电离质谱仪的研制与性能表征. 分析化学, 2018, 46(4): 463-470. doi:  10.11895/j.issn.0253-3820.171415 [复制]

Citation:   YU Jia-Jun, LIU Ping, ZENG Zhen, CHEN Ying, GAO Wei, LI Mei, WANG Chen-Guang, HUANG Zheng-Xu, ZHOU Zhen, LI Lei. Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer. Chinese Journal of Analytical Chemistry, 2018, 46(4): 463-470. doi: 10.11895/j.issn.0253-3820.171415 [复制]

直线式基质辅助激光解吸电离质谱仪的研制与性能表征

通讯作者:  李磊, lileishdx@163.com

收稿日期: 2017-11-11

接受日期: 2017-12-01

出版日期: 2018-04-01

基金项目: 本文系广东省应用型科技研发专项资金(No.2015B020236003)、中央高校基本科研业务费专项资金(No.21616341)资助

Development and Characterization of A Linear Matrix-assisted Laser Desorption Ionization Mass Spectrometer

Corresponding author:  LI Lei, lileishdx@163.com

Received Date:  2017-11-11

Accepted Date:  2017-12-01

Published Date:  2018-04-01

基质辅助激光解吸电离飞行时间质谱仪(MALDI-TOF MS)是一种能够对蛋白质、多肽、核酸等生物大分子进行定性分析的质谱仪器,近年来在微生物快速鉴定领域引起了广泛关注。本研究结合应用需求研制了一台直线式MALDI-TOF MS仪器。仪器主要由真空系统、快速进样系统、光学系统、离子源、飞行时间质量分析器、数据采集系统及电控系统组成。离子源采用双场加速、延迟引出及动态脉冲聚焦技术,整个离子的无场飞行距离为1 m。光学系统采用长寿命的固体激光器,可实现频率1~2000 Hz、聚焦光斑20~100 μm连续可调,能量0~80 μJ连续可调。激光引入光路与离子飞行轴线的角度控制在5°内,有效提高了仪器的灵敏度和分辨率。对仪器进行性能测试表明,可检测的质量数超过199 kDa,在1000~3000 Da范围内可达到同位素分辨,在5000~17000 Da范围内分辨率可达900(FWHM),实现了宽质量范围内的良好分辨率。灵敏度测试表明,仪器对短杆菌肽的最低检测浓度为10 amol/μL,绝对灵敏度可达2.56 amol。不同靶点的唾液样品独立检测结果表明,仪器具有较高的结果重现性。此外,对两种遗传特性相似的大肠埃希氏菌和志贺菌进行检测的结果表明,此仪器能够对这两种特征相似的细菌成功检测和鉴定,具有临床微生物鉴定的潜力。

关键词:   基质辅助激光解吸电离, 直线式飞行时间质谱仪, 研制, 性能表征
Key words:   Matrix-assisted laser desorption ionization, Linear time-of-flight mass spectrometer, Development, Performance characterization
[1]

Fenn J B, Mann M, Meng C K, Wong S F, Whitehouse C M. Science, 1989, 246(4926): 64-71. doi: 10.1126/science.2675315

[2]

Karas M, Hillenkamp F. Anal. Chem., 1988, 60(20): 2299-2301. doi: 10.1021/ac00171a028

[3]

Zhu X Q, Huang Z X, Gao W, Li X, Li L, Zhu H, Mo T, Huang B, Zhou Z. J. Agric. Food Chem., 2016, 64(27): 5614-5619. doi: 10.1021/acs.jafc.6b02101

[4]

WANG Zhong-Hua, CHEN Yan-Hua, XU Jing, CHEN Hui-Li, ZHOU Xia, XIAO Xin-Hua, PING Fan, HE Jiu-Ming, ABLIZ Zeper , ZHANG Rui-Ping. Chinese J. Anal.Chem., 2017, 45(5): 654-661. doi: 10.11895/j.issn.0253-3820.160732

王中华, 陈艳华, 徐婧, 陈蕙莉, 周霞, 肖新华, 平凡, 贺玖明, 再帕尔·阿不力孜, 张瑞萍. 分析化学, 2017, 45(5): 654-661. doi: 10.11895/j.issn.0253-3820.160732

[5]

Vestal M L. J. Am. Soc. Mass Spectrom., 2011, 22(6): 953-959. doi: 10.1007/s13361-011-0108-x

[6]

Prentice B M, Chumbley C W, Hachey B C, Norris J L, Caprioli R M. Anal. Chem., 2016, 88(19): 9780-9788. doi: 10.1021/acs.analchem.6b02821

[7]

Medzihradszky K F, Campbell J M, Baldwin M A, Falick A M, Juhasz P, Vestal M L, Burlingame A L. Anal. Chem., 2000, 72(3): 552-558. doi: 10.1021/ac990809y

[8]

Vestal M L, Hayden K. Int. J. Mass Spectrom., 2007, 268(2): 83-92

[9]

Karas M, Kruger R. Chem. Rev., 2003, 103(2): 427-440. doi: 10.1021/cr010376a

[10]

Spengler B, Kirsch D, Kaufmann R. J. Phys. Chem., 1992, 96(24): 9678-9684. doi: 10.1021/j100203a022

[11]

Tran B Q, Barton C, Feng J H, Sandjong A, Yoon S H, Awasthi S, Liang T, Khan M M, Kilgour D P A, Goodlett D R, Goo Y A. J. Proteomics, 2016, 134: 93-101. doi: 10.1016/j.jprot.2015.10.021

[12]

Rodrigo M A M, Zitka O, Krizkova S, Moulick A, Adam V, Kizek R. J. Pharm. Biomed. Anal., 2014, 95: 245-255. doi: 10.1016/j.jpba.2014.03.007

[13]

Meyer S, Vollmert C, Trost N, Sigurdardottir S, Portmann C, Gottschalk J, Ries J, Markovic A, Infanti L, Buser A. Br. J. Haematol., 2016, 174(4): 624-636. doi: 10.1111/bjh.14095

[14]

Fenselau C, Demirev P A. Mass Spectrom. Rev., 2001, 20(4): 157-171. doi: 10.1002/(ISSN)1098-2787

[15]

Saffert R T, Cunningham S A, Ihde S M, Jobe K E M, Mandrekar J, Patel R. J. Clin. Microbiol., 2011, 49(3): 887-892. doi: 10.1128/JCM.01890-10

[16]

Davies A P, Reid M, Hadfield S J, Johnston S, Mikhail J, Harris L G, Jenkinson H F, Berry N, Lewis A M, El-Bouri K, Mack D. J. Clin. Microbiol., 2012, 50(12): 4087-4090. doi: 10.1128/JCM.02387-12

[17]

Mather C A, Rivera S F, Butler-Wu S M. J. Clin. Microbiol., 2014, 52(1): 130-138. doi: 10.1128/JCM.01996-13

[18]

Ferrand J, Hochard H, Girard V, Aissa N, Bogard B, Alauzet C, Lozniewski A. J. Clin. Microbiol., 2016, 54(3): 782-784. doi: 10.1128/JCM.02758-15

[19]

Vestal M L. Clin. Chem., 2016, 62(1): 20-23. doi: 10.1373/clinchem.2015.239467

[20]

Hattan S J, Parker K C, Vestal M L, Yang J Y, Herold D A, Duncan M W. J. Am. Soc. Mass Spectrom., 2016, 27(3): 532-541. doi: 10.1007/s13361-015-1316-6

[21]

Brown R S, Lennon J J. Anal. Chem., 1995, 67(13): 1998-2003. doi: 10.1021/ac00109a015

[22]

Franzen J. Int. J. Mass Spectrom. Ion. Processes., 1997, 164(1): 19-34

[23]

Bökelmann V, Spengler B, Kaufmann R. Eur. J. Mass Spectrom., 1995, 1(1): 81-93. doi: 10.1255/ejms.163

[24]

Aksouh F, Chaurand P, Deprun C, Della-Negra S, Beyec Y L, Hoyes J, Pinho R R. Rapid Commun. Mass Spectrom., 1995, 9(6): 515-518. doi: 10.1002/(ISSN)1097-0231

[25]

Keys C J, Dare D J, Sutton H, Wells G, Lunt M, McKenna T, McDowall M, Shah H N. Infect. Genet. Evol., 2004, 4(3): 221-242. doi: 10.1016/j.meegid.2004.02.004

[26]

Sauer S, Kliem M. Nat. Rev. Microbiol., 2010, 8(1): 74-82. doi: 10.1038/nrmicro2243

[27]

Arnold R J, Reilly J P. Anal. Biochem., 1999, 269(1): 105-112. doi: 10.1006/abio.1998.3077

[28]

Khot P D, Fisher M A. J. Clin. Microbiol., 2013, 51(11): 3711-3716. doi: 10.1128/JCM.01526-13

计量
  • PDF下载量(39)
  • 文章访问量(254)
  • HTML全文浏览量(13)

目录

直线式基质辅助激光解吸电离质谱仪的研制与性能表征

喻佳俊, 刘平, 曾真, 陈颖, 高伟, 李梅, 王晨光, 黄正旭, 周振, 李磊

Figures and Tables